Installation options.
The modular refrigerator and freezer column concept from Gaggenau offers you a variety of installation possibilities. In some 
instances, special accessories are required!
Individual column installations
Any appliance can be installed as a stand-alone unit. Ensure a cutout 
flush to the appliance at a depth of minimum 4" (102mm), preferably 6" 
(152 mm) on the top and sides.
Note: It is absolutely essential to ensure that the appliance is installed in 
such a way that the doors do not interfere with an adjacent wall or other 
kitchen elements.
Installation options artwork.pdf   1   9/23/2013   4:35 PM
At the end of a cabinetry run
All Gaggenau refrigeration appliances must be completely enclosed on 
the top and sides. If one side of the appliance is visible, a decorative 
side panel must be used for covering it. This side panel must be 
properly affixed to the floor, room wall and any overhead furniture/
fixtures before the appliance is placed in the cutout.
Installation options artwork.pdf   1   9/23/2013   4:35 PM
Side-by-Side installations (SxS)
The proper installation of any side-by-side two column combination 
requires an installation kit (
RA 460 000
). It combines two individual units 
into a side-by-side unit. For combinations that involve freezers and wine 
columns, this kit is already pre-installed to the unit. For all other SxS 
combinations or instances where any appliances are installed less than 
6" (152 mm) apart from another but not connected SxS, a heating kit 
(RA 460 010) is required. 
Note: A partition of minimum ⅝" (16 mm) is required to ensure the 
doors do not interfere with one another when opened. Use a partition 
to separate appliances and observe the door swivel range. (See page 
177 for details on door swivel range dimensions.)
Installation options artwork.pdf   1   9/23/2013   4:35 PM
Multiple column installations with partition walls between
When dimensioning the partition, note the thickness of the door panel 
(including handles) as well as the swivel range (see page 177 on swivel 
range) to prevent damage if the doors are opened at the same time. If 
the thickness of a partition between two products is less than 6", then 
a heating kit (
RA 460 010
) is required. It must be installed on the right 
side wall of the left-side appliance.
Three appliances can be installed together only if a partition — minimum 
⅝" (16 mm) — is placed between two of the appliances. Ensure that 
door panel thickness (including handles) as well as the swivel range are 
accounted for.
Installation options artwork.pdf   1   9/23/2013   4:35 PM
174
 Refrigeration