Electrolux AOFP061C User Manual

Page of 4
Electrolux air-o-chill
Blast Chiller/Freezers 30kg 6GN1/1
Chilling means bringing the temperature of cooked food from +90ºC to +3°C in a short time lap which does not allow 
bacterial growth .Electrolux Blast Chillers/Freezers reduce temperature from +90ºC to +3°C at food core in less than 90 
minutes and down to -18ºC in less than four hours: the model detailed on this sheet performs this cycle up to a 30 kg full 
load. After the Blast Chilling/freezing process a holding cycle starts automatically to respectively maintain food at +3 and 
-18 °C. Blast freezed food has a solid 6 months/1 year shelf life without loss of flavour, nutritional values and weight. The 
opportunity to prepare in a single shot the food to be used in different times during the week enables a better work 
scheduling and therefore a sensible reduction in labour costs.
 
OPERATING MODES
 Cruise: the chiller automatically sets 
the parameters for the quickes and 
best chilling (it works by probe).
 Soft Chilling (Air temperature –2°C).
 Hard Chilling (Air temperature 
–20°C).
 Shock freezing (Low air temperature 
adjustable up to -41 ºC.)
 Holding at +3°C or -18ºC 
(automatically activited at the end of 
each cycle).
 All the probe-driven cycles feature 
ARTE (Algorithm for Remaining Time 
Estimation) to make planning the 
activities easier.
 Holding at +3°C (automatically 
activated at the end of each cycle).
 Turbo cooling: the chiller works 
continuously at the desired 
temperature. Ideal for continuous 
production.
 It is possible to operate by time or 
by probe.
 The control unit provides several 
operating settings: time/core 
temperature according to NF and UK 
regulations, time/air 
temperature/probe personalised 
according to national regulations, 
sterilizing cycle: UV lamps built-in (on 
request), 3 single sensor core 
temperature probes (as accessory), 
ideal for meats, automatic defrosting 
and manual defrosting. All parameters 
are programmable.
 3-sensor core probe as standard 
and automatic detection of the core 
probe insertion.
 The control unit provides two large 
displays to read out: time, core 
temperature, cycle countdown, 
alarms, service information. 
 Suitable for ambient temperatures 
up to 32°C.
 Two specialized cycles, P1 brings 
down ice-cream temperature to -14°C 
(measured at the core when probe is 
inserted). Once set temperature is 
reacheed, the temporary maintenance 
phase automatically begins, holding 
the -14°C temperature. P2 sets 
temperature to -36°C / -40°C for an 
indefinite amount of time, maintaining 
the ventilation active. Temperature is 
adjustable up to -40°C without 
interrupting the cycle, allowing 
ice-cream to be kept longer in the 
freezer. 
 All information related to the 
different operating models are 
recorded: date, time, cycle, core 
temperature, holding temperature, 
HACCP accordance.
 An audible alarm starts when the 