Delfield 400 User Manual

Page of 16
Compact Refrigerators and Freezers Service and Installation Manual
7
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.delfield.com
1. Carefully place the unit on its back (see illustration at right).
2. Located at each caster mounting location are 4 Phillips head 
screws, for a total of 16 screws. Remove them.
3. Place a locking plate caster or leg over one of the front holes, 
matching the 4 mounting holes to the pre-drilled holes in the 
underside of the unit. Insert 4 Phillips head screws and tighten. 
Repeat with the other locking front caster or leg.
4. Repeat step 3 with the non-locking casters or legs in the rear 
of the unit.
5. Carefully lift the unit upright.
After installing casters or legs, the unit must stand 
upright for  twenty-four (24) hours before being 
powered up to assure oil return to the compressor 
sump.
Plate Casters
 W/Locks
Plate Casters
 W/O Locks
Screws
Plate caster installation, 400 & 4000 Series.
Caster Or Leg Installation - 400 & 4000 Series
WARNING
Caster and Leg Mounting Detail
A universal bolt hole pattern is provided on the bottom of the cabinet.  It will accommodate any leg or caster.  Simply line up the plate 
holes with the corresponding cabinet holes.
2.38”
3.40”
1.75”
2.82”
0.94”
2.14”
NOTE:
If hole pattern on caster/leg matches 
the one above mount in inner set of 
holes.  
2” Caster - 3234148
NOTE:
If hole pattern on caster/leg matches 
the one above mount in middle set 
of holes.  
3” Caster - 3234024
5” Caster - 3234161
6” Leg - 3234791
NOTE:
If hole pattern on caster/leg 
matches the one above mount in 
outer set of holes.  
6” Leg - 3234569