The  total  opening  of  the  cabinet  (i.e.  70-3/8  in.
(1788 mm)) plus the thickness of the top as well as the
floor board (usually 3/4 in. (19 mm)) minus the height of
the freezer door panel (xxx in. (xxx mm)) as calculated
above and subtract the width of the gap (approximately
1/8 in. (3 mm)): 70-3/8 in. + 3/4 in. + 3/4 in. - xxx in. -
1/8 in. = 71-25/32 in. - xxx in. ( 1788 mm + 19 mm +
19 mm - xxx mm - 3 mm = 1823 mm – xxx mm )
5 Water supply*
WARNING
Electrical Shock Hazard!
u
Do not make the water connection while the appliance is
connected to an electrical outlet.
u
Disconnect the water supply before connecting the water
lines for the IceMaker.
u
The connection to the water supply may only be made by
a trained and licensed plumber.
WARNING
Poisoning Hazard!
u
The water quality must comply with the drinking water
regulations  for  the  geographical  area  where  the
appliance is located.
u
The IceMaker is designed exclusively to make ice cubes
in quantities needed by a household and must only be
operated with water appropriate for this purpose.
- The  water  pressure  must  be
between 21.76 psi (1.5 bar) and
87.02 psi (6 bar). (0,15 MPa -
0,6 MPa)
- Water must be supplied to the
appliance by means of a cold-
water  pipe  that  can  withstand
the  operating  pressure  and
conforms 
to 
hygiene
regulations.
Use  the  supplied  steel  hose
(59-1/16  ''  (1.5  m),  metric
thread) to connect to the water
supply. A 118-1/8 '' (3 m) hose
is  available  from  Customer
Service.  This  hose  must  be
installed by a qualified fitter.
The  connecting  piece  of  the
hose  contains  a  filter  with  a
gasket seal.
- A  shut-off  valve  must  be
provided between the hose line
and the domestic water supply
to  turn  off  the  water  supply,  if
necessary.
- All devices and fixtures used to
supply water must comply with
the  regulations  in  force  in  the
respective country.
- Do  not  damage  or  bend  the
water  supply  pipe  during
installation.
u
Connect  the  straight  portion  of  the  supplied  stainless
steel hose to the solenoid valve.
The solenoid valve is located on the back of the appliance
at the bottom. It has a Metric R¾ male connection.
u
Connect the bent portion of the stainless steel hose to
the shut-off valve.
u
Open  the  shut-off  valve  of  the  water  supply
pipe  and  check  the  entire  water  system  to
ensure there are no leaks.
Before initial operation:
u
Have a competent fitter bleed the water supply
pipe.
6 Installation
All installation components are supplied with the appliance.
Fig. 8 
Make sure you have the following tools on hand:
q
Cordless Torx 15. 20. 25 screwdrivers
q
Hexagonal wrench 13
The floor and side walls of the unit must be at right angles
to one another. Level the unit using a spirit level and set
square.  If  necessary,  level  up  by  placing  something
underneath.
The  appliance  can  also  be  built  into  a  normal  kitchen
cabinet. In this case, detach the fittings on the unit door and
the recess. They are no longer needed, as the unit door is
fitted to the appliance door.
Water supply
8