Tricity Bendix SG552D User Manual

Page of 36
 
35 
  Fix lower bracket (with two fixing holes) 
to the floor then measure the height from 
floor level to engagement edge on back 
of appliance, dimension 'C' of Fig. 3b. 
4.  Assemble upper bracket to lower bracket 
so  that  the  underside  of  bracket  is 
dimension  'C' +  3mm  above  floor  level.  
(See Fig. 3b) 
Reposition appliance and check that top 
bracket engages into appliance back as 
shown in Fig. 3b. 
Pressure testing 
1.  The oven injector is used as a pressure 
test point. 
2.  Connect  the  pressure  gauge  to  the 
oven injector.  
3.  Check  the  supply  pressure  by  turning 
the  oven  burner  on  and  one  other 
hotplate  burner  full  on  and  light  the 
appropriate burner. 
The pressure should be :- 
(i) 
For Natural Gas 20mbar  
4.  Turn  off  the  taps,  disconnect  the 
pressure gauge. 
5.  Check  operation  of  each  hotplate 
burner. 
Checking the grill 
Place  the  grill  pan  containing  the  grid  with 
the  handle  attached  in  to  the  grill 
compartment.  To  light  the  grill  push  in  and 
hold  the  control  knob,  turn  to  large  flame 
symbol  (highest  setting)  and  press  the 
ignition button immediately. Keep the control 
knob depressed for up to 5 seconds but no 
longer  than  10  seconds.  After  this  time 
release  the  controls.  The  flame  should 
remain alight. 
 
Checking the hotplate
   
Fit the burner crowns and caps ensuring that 
they  are  correctly  seated.  Fit  the  pan 
supports. To light the hotplate burners push 
in  and  hold  the  control  knob,  turn  to  large 
flame symbol (highest setting) and press the 
ignition button immediately.   
Keep the control knob depressed for up to 5 
seconds,  but  no  longer  than  10  seconds.  
After  this  time  release  the  controls.    The 
flame should remain alight.   
Turn  off  the  hotplate  and  wait  1  minute.  
Turn the hotplate control knob to large flame 
symbol (highest setting).  DO NOT depress 
or  attempt  to  ignite  the  burner.    No  gas 
should flow. 
Checking the main oven 
1.  Turn  on  the  oven  thermostat  control 
knob to mark 9. As soon as the burner 
is alight the button can be released. 
2.  There should now be a low gas rate to 
the  burner,  which  is  the  F.S.D  bypass 
rate. 
3.  When the F.S.D. phial has heated up it 
opens the F.S.D valve which allows the 
main gas supply to the oven burner. 
4.  After  1  minute  check  that  the  flame 
covers the full width of the burner and is 
stable. 
5.  Set the oven control to Mk 2, close the 
oven door and check that after about 10 
minutes the flame size has reduced. 
6.  Turn off the control and check that the 
oven flames go out. 
 
General note 
Instruct the user on how to use the appliance 
and its ignition system.  Refer the user to the 
wording  on  the  inside  cover  which  gives 
advice  on  the  safe  operation  of  the 
appliance.