Lexmark C762 User Manual

Page of 402
PostScript
4-62
 
Interpreter Parameters
This section describes the PostScript emulation interpreter parameters. There are 
three types of interpreter parameters:
User parameters
System parameters
Device parameters
To determine which parameters your printer supports, see Appendix C: “PostScript 
Support” on page C-1.
User Parameters
The following user parameters are used by 
setuserparams
 and 
currentuserparams
.
If a value is requested that is not within the range for the requested parameter, the 
minimum (or maximum) value is used.
If a 
setuserparams
 value does not match the type of the specified parameter, a 
typecheck
 error occurs. If a parameter is not supported by the printer, it is ignored. 
An attempt to change the value of a read-only parameter has no effect on the 
parameter.
To determine which parameters your printer supports, see Table C-3 on page C-8.
Table 4-9:  PostScript Emulation User Parameters
Key
Type
Definition
AccurateScreens
boolean
Controls whether the accurate screen algorithm is used during subsequent 
executions of the 
setscreen
 and 
setcolorscreen
 operators.
CollatedCopies
integer
Requests the number of collated copies to print for the job. The 
CollatedCopies
 
parameter must be set before the first page of the job has been sent.
If 
CollatedCopies
 is set to zero, the parameter has no effect on the job. If 
CollatedCopies
 is set to a number other than zero, the value of #copies and of 
the 
NumCopies
 and 
Collate
 pagedevice parameters are ignored for the job.
Legal values: Any integer between 0 and 999, inclusive.