Interfaces
8-11
 
Controls data flow control with BUSY and ACKNLG* signals. Does not carry 
out data transfer by ignoring the BUSY or ACKNLG* signal. (The system can 
carry out data transfer to the printer only when the level of the BUSY signal is 
low and after confirming the ACKNLG* signal is high.)
Uses standard transistor-transistor logic (TTL) levels for all interface control 
signals and input data. Interface conditions are based on TTL levels. All 
printer outputs are totem-pole TTL devices. All printer input/output (I/O) are 
devices with an internal pull-up resistor to 5 V. Rise and fall times of each 
signal must be less than 1,500 nanoseconds (ns) without slope reversal.
Standard Protocol Data Transfer Sequence
The following illustration shows the typical data transfer sequence on the parallel 
interface. See Table 8-1 for typical parallel interface timings on the parallel interface.
DATA1-8
STROBE*
BUSY
ACK*
A
B
C
D
E
F
G