Lexmark C762 User Manual

Page of 402
PCL
2-32
 
Command Structure
Most PCL emulation commands have the following structure:
ESC
 & a # C
Spaces have been added to this example for readability. The command parameter 
variables are indicated by a number sign (#).
Command Parameters
A command parameter sets the value for a command. This value stays constant until 
either a different value resets the command or a command resets the printer to the 
default values. For example, after the printer receives a command that selects a right 
margin beginning at column 63, the right margin of each printed page begins at 
column 63. That margin stays constant until a right margin command with a different 
value resets it or until the printer is reset.
Parameters for each command are listed in the command tables beginning on 
page 2-34. Use the Symbol Set Tables to determine the decimal or hexadecimal value 
for each parameter. To determine a decimal or hex value, first locate the value of the 
parameter you require in the Symbol Set Table. The decimal value is the value shown 
in the bottom of the cell or box with that parameter. To find a hex value, go straight up 
the grid from the desired parameter and read the value in the top heading. This is the 
first character of the hex value. Next, go straight across the grid to the left of the 
parameter and read the value in the left column heading. This is the second character 
of the hex value. For example, 
ESC
 (
) is coded 1B in Hex and 27 in decimal. (Any one 
of the three values 
, 1B, or 27 might be used in your application. Read your 
documentation to determine which to use.) The example on the following page sets 
the pitch of the primary font to 16.66 characters per inch.
Table 2-10:  Description of Command Structure
Element
Description
ESC
Decimal 27 or hex 1B
&
Parameterized character from American National Standard Code for Information 
Interchange (ASCII) table (ranging from 33 to 47 decimal)
a
Group character from ASCII table (ranging from 96 to 126 decimal) that specifies a 
group type of control
#
Decimal character string value within specified numeric ranges; may be preceded by 
a + or - sign and contain a decimal point
C
Termination character from ASCII table (ranging from 64 to 94 decimal)