Smeg SSA91MFX User Manual

Page of 24
 
 
Instructions for the installer 
 
 
 
3.2
 
Burner and nozzle characteristics table (Mod. 90 cm.) 
 
 
 
 
Burner 
Rated 
heating 
capacity 
(kW) 
 
LPG
 
 
G30/G31
  
28/37
 
mbar 
 
 
 
Nozzle  
diameter 
1/100 mm 
By-pass 
mm 
1/100 
Reduced  
flowrate 
(W) 
Flowrate  
g/h G30 
Flowrate  
g/h G31 
Auxiliary 
1.0 
50 
30 
350 
73 
71 
Semi rapid 
1.75 
65 
33 
450 
127 
125 
Rapid 
3.0 
85 
45 
800 
218 
214 
Triple crown 
3.2 
91 
65 
1500 
233 
229 
Oven 
3.2 
87 
48 
850 
233 
229 
Maxi oven 
5.2 
110 
59 
1200 
378 
371 
Grill 
4.0 
100 
// 
// 
291 
286 
 
 
 
 
Burner 
Rated  
heating  
capacity 
(kW) 
 
NATURAL GAS –
 
G20
  
20
 
mbar 
 
 
Nozzle diameter 
1/100 mm 
Reduced flowrate 
(W) 
Auxiliary 
1.0 
72 
350 
Semi rapid 
1.75 
97 
450 
Rapid 
3.0 
115 
800 
Triple crown 
3.5 
140 
1500 
Oven 
3.2 
130 
850 
Maxi oven 
5.2 
164 
1200 
 
 
 
3.3
 
Arrangement of the burners on the hob (Mod. 90 cm.) 
 
 
 
BURNERS 
 
1
 
Auxiliary 
2
 
Semi rapid 
3
 
Rapid 
4
 
Triple crown 
 
 
10