Instructions for the installer 
 
14
 
 
4  ADJUSTMENT TO DIFFERENT TYPES OF GAS 
 
 
 
Before performing any cleaning or maintenance work, unplug the 
appliance from the mains. 
 
 
 
 
 
The hob of the cooker is adjusted for use with either natural gas at a 
pressure of 1.0 kPa. If used with other types of gas, you have to replace 
the nozzles, then adjust the minimum flame on the gas taps. For nozzle 
replacement and burner adjustment operate as described in the following 
paragraph. 
 
 
 
 
 
4.1  Replacement of nozzles on the hob 
 
 
 
 
 
1.  Remove the grids and all the caps and flame-spreader crowns; 
2.  Unscrew the burner nozzles with a 7 mm socket wrench; 
3.  Replace the nozzles according to the type of gas to be used (see 
paragraph “3.2 Burner and nozzle characteristics table”). 
4.  Replace the burners in the correct position.