Smeg CS150SA User Manual

Page of 43
11
Instructions for the Installer
3.2
Burner and nozzle characteristics table
Burner
Rated 
heating 
capacity
(kW)
LPG – G30/G31  28/37 mbar
(drawing ref. X238)
Nozzle 
diameter
1/100 mm
By-pass
Mm
1/100
Reduced 
flowrate
(W)
Flowrate 
g/h G30
Flowrate 
g/h G31
Auxiliary
1.05
50
30
400
76
75
Semi rapid
1.8
65
33
500
131
129
Rapid
3.0
85
45
800
218
215
Fish Burner
1.9
68
45
800
138
136
Ultra rapid
4.0
100
65
1600
291
286
UR2 Inner ring
1.0
46
30
400
73
71
UR2 Outer ring
3.6
68+68
65
1600
284
250
Burner
Rated 
heating 
capacity
(kW)
NATURAL GAS – G20  20 mbar
Nozzle diameter
1/100 mm
Drawing
Ref.
Reduced flowrate
(W)
Auxiliary
1.05
72 
(X)
400
Semi rapid
1.8
97 
(Z)
500
Rapid
3.0
115 
(Y)
800
Fish Burner
1.9
94 
(X)
800
Ultra rapid
4.0
135
(K)
1600
UR2 Inner ring
1.0
  70
(X)
400
UR2 Outer ring
3.6
102 +102
(Z)
1600
3.3
Hob burner layout
BURNERS
1
Auxiliary
2
Semi rapid
3
Rapid
4
WOK
5
Fishpan