Sierra 840 User Manual

Page of 74
Series 830/840/860 Instruction Manual 
Appendix B Specifications
 
IM-83/84/86-H 
B-1
 
Appendix B   Product Specifications
 
Operating Specifications
 
 
Gases 
All clean gases; specify when ordering 
 
Mass Flow Rates 
0 to 10 sccm to 0 to 5600 slpm; flow ranges specified are for an equiva-
lent flow of nitrogen at 760 mm Hg and 21°C (70°F); other ranges in 
other units are available (e.g. scfh or nm
3
/h) 
 
Gas Pressure 
1000 psig (68.9 barg) maximum for low flow bodies only; 
 
500 psig (34 barg) maximum; 30 psig (2 barg) optimum 
 
Gas & Ambient Temperature 
 
 
32° to 122°F (0 to 50°C); higher available on special order 
 
Leak Integrity   
5 X 10
-9
 atm cc/sec of helium maximum 
 
Pressure Drop  
830/860M (low) .......0.08 psi (0.006 bar or 6 cm of water) differential max; 
 
 
 
 
15 slpm: 1.5 psi (0.20 bar or 1.5 cm of water) differential max 
 
 
 
830/860M (med)......0.08 psi (0.006 bar or 6 cm of water) differential max; 
 
 
 
 
100  slpm:  1.5  psi  (0.20  bar  or  1.5  cm  of  water)  differential 
max 
 
 
 
830/860M (high) ......0.08 psi (0.006 bar or 6 cm of water) differential max; 
 
 
 
 
300, 400 and 500 slpm: 2 psi (0.15 bar or 140 cm of water) 
 
 
 
 
differential maximum 
 
 
 
830 NPT ..................1.5 psi (0.20 bar or 1.5 cm of water) differential maximum 
 
Differential Pressure Requirements 
 
 
 
840/860C (low)........5 to 50 psi (1.0 to 3.4 bar) differential standard; 
 
 
 
 
30  psi  (2.1  bar)  differential  optimum;  lower  (10  Torr  mini-
mum) 
 
 
 
 
or higher (100 psi maximum) ∆P available on special order 
 
 
 
840/860C (med) ......20, 30 and 50 slpm: 5 to 50 psi (1.0 to 3.4 bar) differential; 
 
 
 
 
100 slpm: 15 to 50 psi (1.0 to 2.8 bar) differential standard; 
 
 
 
 
30 psi (2.1 bar) differential optimum; lower or higher ∆P 
 
 
 
 
available on special order 
 
 
 
840/860C (high) ......100 and 200 slpm: 10 to 50 psi (1.0 to 3.4 bar) differential; 
 
 
 
 
300, 400 and 500 slpm: 10 to 40 psi (0.7 to 2.8 bar) differ-
ential 
 
 
 
 
standard;  30  psi  (2.1  bar)  differential  optimum;  lower  or 
higher 
 
 
 
 
∆P available on special order 
 
 
 
840 (NPT) ................10 to 50 psi (0.7 to 3.4 bar) differential standard; 
 
 
 
 
30 psi (2.1 bar) differential optimum; lower or higher ∆P 
 
 
 
 
available on special order 
 
Power Requirements 
830/860M ................+ 15 VDC @ 80 mA,  1.2  watts and -15  VDC @  10  mA, 0.15 
watts 
 
 
 
840/860C (low)........+15  VDC  @  80  mA,  1.2  watts  and  -15  VDC  @  175  mA,  2.6 
watts 
 
 
 
840/860C (med) ......+15  VDC  @  220  mA,  3.0  watts  and  -15  VDC  @  175  mA,  2.6 
watts