Analog inputs 
The analog inputs of the ICOM-241 have an input range from 0...5V DC. The 
hardware resolution is 10 bit and can be raised to 12 bit by software 
interpolation when needed. To be able to measure small signals each analog 
input is equipped with an OpAmp. The amplification can be set to a value 
between 1 and 10 by potis. 
 3 
View of components side with potis of analog amplifiers 
 
Analog channels 
DB25 socket 
An0 22 
An1 23 
An2 24 
An3 25 
Pin layout of DB25 connector (analog channels) 