Lucent Technologies 5 User Manual

Page of 429
MERLIN LEGEND Communications System Release 5.0
System Manager’s Guide  
555-650-118  
Issue 1
June 1997
Managing the System 
Page 6-21
Programming from a PC with SPM 
6
With a Local or Remote Modem Connection
6
The method you use to access SPM by modem depends on whether you are 
programming on site (locally) or from a remote location. 
If you are on site, the modem must be connected to a 012 or a 016 
(Release 4.0 and later only) module on the control unit. To establish a 
connection to the control unit’s internal modem, dial 
*10
If you are at a remote location, do one of the following:
— Place a call to the system on a remote access line, enter the barrier 
code (if required), and dial the code for the internal modem (
*10
).
— Place a voice call to the system on a regular line and ask the operator to 
transfer you to the modem (by dialing
 
*10
). 
When you hear the modem 
answer tone, switch to data mode.
Modem Connections
6
You must make a data connection to a modem. The following modem dialing 
commands work for most modems. These may not be the commands your 
modem uses; refer to the user guide that came with your modem for specific 
information.
If the PC is in the same location as the control unit, type 
*10
.
If the PC is in a remote location and your system has activated the Remote 
Access feature, type the following:
ATDT
the remote access telephone number, and 
W*10
Then press 
2
For example: 
ATDT12015551234 W*10
 
2
. Also, a barrier code (4 to 11 
digits) may be required between the 
ATDT
 and the 
W*10
 entries. For 
example:
 ATDT12015551234 W1234567 W*10
.
When the connection is made, the password prompt appears on the 
screen. (You may have to press 
2
 more than once to get the 
password prompt.)
NOTE:
If you enter a telephone number of fewer than 11 digits, you must end it 
with a pound sign (#). 
If the PC is in a remote location and your system has not activated the 
Remote Access feature, do the following:
1.
Use the main telephone number to place a voice call to the system.
2.
Instruct the operator to transfer the call to the modem by transferring 
the call to 
*10
3.
Put the modem on line by switching it to data mode.