Managing the System 
Page 6-57
Adding a DLC Operator Position 
6
Adding a DLC Operator Position
6
Use this procedure to add a DLC operator position to either an MLX or an analog 
multiline extension module.
To add a QCC operator position, see the next section, 
Planning Guidelines
6
DLC operator positions can be assigned to the first and fifth extension jacks on 
any MLX or analog multiline module. The first jack on the first extension module in 
your system is automatically assigned as the primary operator position.
If your system has Call Management System (CMS), the two CMS connections 
must be made to analog jacks. Each CMS requires two DLC operator positions on 
the same analog module to connect the equipment and one position to serve as 
CMS supervisor.
A maximum of eight DLC operator positions can be assigned. Any combination of 
operator positions can be assigned as long as there are not more than four QCC 
operator positions (Hybrid\PBX) and no more than a total of eight operator 
positions (see 
). 
Table 6–10.  Maximum Number of Operator Positions
Lines and trunks are assigned on individual buttons.
NOTE:
Because this procedure requires an idle system, you may want to perform 
it after hours. Also, when you change an extension to or from an operator 
position, the system returns the port (extension jack) type of that extension 
to the factory setting. You must reprogram lines and any features for that 
telephone or console. You may also need to reprogram any attached 
adjunct equipment and optional features.
Position Type
Type of Telephone
Maximum 
Positions
QCC
MLX-20L
4
DLC
MLX-20L 8
MLX-28D
BIS-34D, BIS-22, or BIS-22D 
analog multiline telephone
MERLIN II Display Console