• The unreadable sectors that are detected on the storage array
• The state capture data
• An inventory of the versions of the firmware running on the RAID controller modules, the physical 
disks, and the RAID controller modules
Syntax
save storageArray supportData file="filename"
[force=(TRUE | FALSE)]
Parameters
Parameter
Description
file
The path and the file name where support-related 
data for the storage array is saved. Enclose the file 
path and the file name in double quotation marks (" 
"). For example, file="C:\Program Files\CLI
\logs\supdat.zip". This command does not 
automatically append a file extension to the saved 
file. A file extension must be specified when 
entering the file name.
force
Forces collection of support data when there is a 
failure in securing a lock on RAID controller 
module operations. To force the collection of 
support data, set this parameter to TRUE. The 
default value is FALSE.
Schedule Support Bundle Collection Configuration
Description
This command specifies a schedule for collecting support bundle data.
NOTE: This command must be run from the command line. It cannot be run in the MD Storage 
Manager script editor.
Syntax
SMcli -supportBundle schedule (enable|disable) (all|storageArrayName)
[data=pathName]
[startTime=HH:MM]
[startDate=MM:DD:YY]
[endDate=MM:DD:YY]
(daysOfWeek={} | months={}
(onDays={} |
weekNumber=(First|Second|Third|Fourth|Last) dayOfWeek=(Sunday|Monday|Tuesday|
Wednesday|)
282