DELL 34XX User Manual

Page of 417
Start Configuration Database Diagnostic
Description
This command starts a diagnostic test to validate the configuration database in the RAID controller 
module firmware.
Syntax
start storageArray configDbDiagnostic
Parameters
None.
Notes
Upon completion of the diagnostic test, the RAID controller module firmware returns one of these 
results:
• Diagnosis completed without errors. No ZIP file created.
• Diagnosis completed with errors. Refer to the ZIP file created at:
...\Install_dir\data\FirmwareUpgradeReports\timestamp_buildNo.zip
If the diagnostic test detects an inconsistency in the configuration database, the RAID controller module 
firmware performs these actions:
• Returns a description of the inconsistency.
• Saves a ZIP file containing raw binary data.
The RAID controller module firmware saves the ZIP file to this location:
...\Install_dir\data\FirmwareUpgradeReports\timestamp_buildNo.zip
The binary data can be used to help determine the cause of the problem, or the file containing the binary 
data can be sent to a Customer and Technical Support representative.
To stop the database configuration diagnostic test, use the stop storageArray 
configDbDiagnostic command.
In addition, the database configuration diagnostic test can be started using the storage management 
software GUI but cannot be stopped using the storage management software GUI. If you want to stop a 
running diagnostic test, you must use the stop storageArray configDbDiagnostic command.
Start Consistency Group Snapshot Rollback
Description
This command starts a rollback operation to the member base virtual disks in a snapshot consistency 
group. The content of the base virtual disks changes immediately to match the point-in-time content of 
the consistency group snapshot virtual disk. The base virtual disks immediately becomes available for 
378