Stop Storage Array Blink
Description
This command turns off the indicator lights on the storage array that were turned on by the start 
storageArray blink command.
Syntax
stop storageArray blink
Parameters
None.
Stop Storage Array Configuration Database Diagnostic
Description
This command stops the diagnostic test to validate the configuration database in the RAID controller 
module firmware that was started by the start storageArray configDbDiagnostic command.
Syntax
stop storageArray configDbDiagnostic
Parameters
None.
Notes
The RAID controller module firmware returns a confirmation that the diagnostic test was cancelled.
In addition, you can start the database configuration diagnostic test through the storage management 
software GUI; however, you cannot stop the database configuration diagnostic test through the storage 
management software GUI. If you want to stop a running diagnostic test, you must use the stop 
storageArray configDbDiagnostic command.
If you try to use the stop storageArray configDbDiagnostic command after validation of the 
storage array configuration is complete, you do not receive any message that the validation has finished. 
This behavior is expected.