DELL 32XX User Manual

Page of 417
Parameter
Description
snapVirtualDisk
The alphanumeric identifier (including - and _) of 
the snapshot virtual disk on which to run a 
consistency check. Enclose the snapshot virtual 
disk identifier in square brackets ([ ]).
virtualDisk
The alphanumeric identifier (including - and _) of 
the thin virtual disk on which to run a consistency 
check. Enclose the virtual disk identifier in square 
brackets ([ ]).
virtualDiskCopy
Specifies that the target of a virtual disk copy 
relationship is checked for consistency.
target
Use only in conjunction with the 
virtualDiskCopy parameter to specify the 
alphanumeric identifier of the virtual disk that is the 
target of the virtual disk copy relationship. Enclose 
the virtual disk identifier in double quotation marks 
(" ").
file
The file path and the file name to which you want 
to save the report that results from the consistency 
check. Enclose the file name in double quotation 
marks (" "). For example: file="C:\Program Files\CLI
\logs \repoConsistency.txt". This parameter must 
appear last, after any of the optional parameters.
Check Storage Array Connectivity
Description
This command verifies that the local storage array and the remote storage array have a communication 
path and displays the connection details between the local and remote storage array.
Before creating a remote replication group, you should check whether the local storage array and the 
remote storage array can communicate with each other. When you execute this command, the system 
queries for the remote storage array on all eligible host ports to determine what ports are connected to 
the remote storage array. The result of the test is a list of all ports on the local storage array along with a 
list of the remote storage array port addresses accessible through that port.
NOTE: Connectivity is tested using all possible channels, and if it is a dual RAID controller module 
configuration, connectivity is checked from each RAID controller module. It might take up to 20 
minutes to check connectivity between two storage arrays.
Syntax
check storageArray connectivity  (remoteStorageArrayName="storageArrayName" | 
remoteStorageArrayWwid=<wwID>)
147