DELL 32XX User Manual

Page of 417
Set Physical Disk State
Description
This command sets a physical disk to the Failed state. To return a physical disk to the Optimal state, use 
the revive physicalDisk command. Optionally, you can copy the data from the physical disk before you 
fail it.
Syntax
set physicalDisk [enclosureID,drawerID,slotID] 
operationalState=failed
[copyPhysicalDisk]
Parameters
Parameter
Description
physicalDisk or physicalDisks
The enclosure and the slot where the physical disk 
resides. Enclosure ID values are 0 to 99. Slot ID 
values are 0 to 31. Enclose the enclosure ID values 
and the slot ID values in square brackets ([ ]).
copyPhysicalDisk
This parameter copies the data from the physical 
disk that you are replacing to the replacement 
physical disk.
Set RAID Controller Module
Description
This command defines the attributes for the RAID controller modules.
Syntax
set controller [(0 | 1)] 
[availability=(online | offline | serviceMode)] 
[ethernetPort [(0 | 1)] ethernetPortOptions
[globalNVSRAMByte [nvsramOffset]=(nvsramByteSetting | nvsramBitSetting)] 
[hostNVSRAMByte [hostTypenvsramOffset]=(nvsramByteSetting | 
nvsramBitSetting)] 
[IPv4GatewayIP=ipAddress
[IPv6RouterAddress=ipv6Address
[iscsiHostPort [(0 | 1 | 2 | 3)] iscsiHostPortOptions
[rloginEnabled=(TRUE | FALSE)] 
[serviceAllowedIndicator=(on | off)]
299