4. OPTIONAL EQUIPMENT 
 
4-5
4.3 Remote Display 
The FURUNO Display Unit FMD-811, MODEL1832 or GD-280/380, etc. can be connected 
to this radar as a sub display. The display unit RDP-150 also can be used as a sub display. 
To interconnect them, use optional cable MJ-B24LPF0008-100/200/300 (see page iv). Also, 
the EMI core (option) should be attached to the remote display cable to prevent noise. 
 
Installation materials for remote display (Type: CP03-31001、Code number: 008-556-830) 
 
Name Type Code 
no. 
Qty 
1 EMI 
core 
RFC-H13 
000-146-570-10 
2 Cable 
clamp 
CK-13H 
000-102-947-10 
3 Cable-tie 
CV-100N 
000-162-167-10 
4 Cable-tie 
CV-150N 
000-162-186-10 
 
1.  Unscrew all connector nuts at the rear of the main display unit. 
2.  Unfasten all screws to remove the display cover. 
3.  Pass the signal cable from the “OPTION” port at the rear of the display unit through the 
hole shown in the figure below and then connect it to the SPU board. 
4.  Fix the shield wire with a screw used to fixed the SPU board. 
5.  Attach the EMI core RFC-H13 on the signal cable. 
6.  Attach cable clamp and fix the cable as shown below. 
90 mm
EMI core
RFC-H13
Attach cable-tie approx. 90 mm from the end of
cable and attach EMI core.
Remote display cable
Fix the EMI core with cable-tie CV-100.
Cable clamp