Toshiba E-STUDIO281C User Manual

Page of 602
e-STUDIO281c/351c/451c ADJUSTMENT
June 2005 © TOSHIBA TEC
3 - 12
[F] Secondary scanning data laser writing start position
This adjustment has to be performed for each paper source.
The following table shows the order of the paper source to be adjusted, code, paper size and accept-
able values.
(1) While pressing [0] and [5] simultaneously, turn the power ON. 
→ (Adjustment Mode)
(2) Press [1] ([3] for duplexing) 
→ [FAX]. (A grid pattern with 10 mm squares is printed out.)
(3) Measure the distance D from the leading edge of the paper to the 6th line of the grid pattern.
* Normally, the 1st line of the grid pattern is not printed.
* At the duplexing, measure it on the top side of the grid pattern.
(4) Check if the distance D is within 52±0.5 mm.
(5) If not, use the following procedure to change values and measure the distance D again.
<Procedure> 
(Adjustment Mode) 
→ (Key in the code shown above) → [START]
→ (Key in an acceptable value shown above)
→ [ENTER] or [INTERRUPT] (Stored in memory)
→ "100% A" is displayed
→ Press [1] ([3] for duplexing)
→ [FAX] → (A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance D becomes (approx. 0.2 mm/step).
[G] Primary scanning data laser writing start position at duplexing
Note: 
Note: 
Make sure the first line of the grid pattern is printed out since the line is occasionally vanished.
[G-1]
Adjustment for long-sized paper
(1) While pressing [0] and [5] simultaneously, turn the power ON. 
→ (Adjustment Mode)
(2) Press [3] 
→ [FAX]. (A grid pattern with 10 mm squares is printed out. Use A3/LD from the lower 
drawer.)
(3) Check the grid pattern on the test print and measure the distance E from the left edge of the 
paper to the 6th line of the grid pattern.
(4) Check if the distance E is within 52±0.5 mm.
(5) If not, use the following procedure to change values and measure the distance E again.
<Procedure>
 (Adjustment Mode) 
→ (Key in the code [498]) → [START] → [0] → [START]
→ (Key in a value (acceptable values: 0 to 255))
→ [ENTER] or [INTERRUPT] (Stored in memory)
→ "100% A" is displayed.
→ Press [3] → [FAX] → (A grid pattern is printed out.)
* The larger the adjustment value is, the longer the distance E becomes (approx. 0.04 mm/
step).
Order for 
adjustment
Paper 
source
Code
Paper size
Acceptable 
value
Remarks
1
Lower 
drawer
441
A3/LD
0 to 80
2
Upper 
drawer
440
A4/LT
0 to 40
3
PFP or LCF
444/443
A4/LT
0 to 40
4
Bypass feed
442
A4/LT
0 to 40
5
Duplexing
445
A3/LD
0 to 40
Paper fed from the lower drawer