Furuno SC-50 User Manual

Page of 82
4. MAINTENANCE, TROUBLESHOOTING
 
 
4-2 
4.2 Troubleshooting 
This section provides basic troubleshooting procedures which the user may 
follow to restore normal operation. 
Troubleshooting 
Symptom Cause  Remedy 
Power connector on the 
processor unit 
Firmly connect the power 
connector. 
Power supply failure 
Check the power supply. 
Cannot turn on the power. 
Blown fuse 
Have a qualified 
technician check the fuse.
Heading indication 
changes randomly when 
ship is at anchor or does 
not change when ship 
moves. 
Sensor trouble 
Run the diagnostic test2 to 
determine cause. 
Connection between 
SC-50 and external 
equipment has loosened. 
Firmly fasten the 
connector. 
Heading output from 
SC-50 does not appear on 
external equipment. 
Sensor trouble 
Run the diagnostic test1 to 
determine the cause. 
If large heading error occurs or heading indication is frequently interrupted, 