Furuno SC-50 User Manual

Page of 82
4. MAINTENANCE, TROUBLESHOOTING
 
 
4-9
4.7 Replacement 
of 
Fuse 
The 3 A fuse on the POWER Board inside the processor unit protects the 
equipment from overcurrent and reverse polarity of the power supply. If the fuse 
blows, have a qualified technician check the fuse. 
WARNING
Use the proper fuse.
Use of a wrong fuse can result in damage
to the equipment or cause fire.
 
 
 
4.8 Error 
Messages 
The alarm sounds for equipment error and is accompanied by a flashing 
exclamation mark ( ). Press any key to silence the alarm. The exclamation 
mark remains on the screen until the cause for error is eliminated. Find the 
cause for the alarm(s) as follows: 
 
1.  Press the [MENU] key to open the menu. 
2.  Choose MESSAGES and then press the [ENT] key. 
MESSAGES
GPS DATA ERROR!
 
Message display 
3.  Press the [DISP] key to close the menu. 
Error messages 
Error Message 
Meaning 
Remedy 
ABORTING! 
GPS heading error continues for 
one minute. For example, satellite 
cannot be acquired because of 
unfavorable environment. 
Check for obstruction. 
ABORTING CALC! 
GPS signal lost for one minute. 
Press any key to try to restore 
normal operation. 
BACKUP ERROR!(DISP)  Corrupted backup data found in 
display unit at power on. 
Default settings are 
automatically restored. 
BACKUP 
ERROR!(PRCSSR) 
Corrupted backup data found at 
processor unit at power on. 
Default settings are 
automatically restored. 
(Continued on next page)