Siemens S120 User Manual

Page of 301
 
Motor components of the built-in motor and options 
 
3.2 Thermal motor protection 
Table 3- 3 
Technical data of the KTY 84 PTC thermistor 
Name 
Description 
Type 
KTY 84 
Transfer range 
- 40 °C ... + 300 °C 
Resistance when cold (20 °C) 
approx. 580 Ω 
Resistance when hot (100 °C) 
approx. 1000 Ω 
Connection 
Connect signal cable with connector to SME12x module. 
Application 
Temperature monitoring to determine the motor utilization. 
Temperature characteristic 
 
5HVLVWDQFH˖
7HPSHUDWXUHr&
,7HVW P$







  
               
 
 
 
 
DANGER 
 
Electrical shock hazard! 
To fulfill the requirements of electrical separation in accordance with EN 61800-5-1, it is not 
enough to connect the signal cable (cores ws and br) to the SMC20 Sensor Module. The 
temperature monitoring circuits must be connected to the drive control via the SME12x 
module. 
 
 
 
NOTICE 
 
When connecting temperature sensors with open cable ends, please pay attention to how 
the core colors are assigned (described in the section dealing with connections). 
 
 
1FW6 Built-in torque motors 
Configuration Manual, 05/2009, 6SN1197-0AE00-0BP3 
47