Meter Operation
309497L
15
 
6.
If the operator wants to top-off fluids, press the left 
arrow key to display the TOP-OFF MODE. See F
19.
7.
Pull the trigger to dispense the desired fluid amount 
for top-off.
8.
Press END to complete the job. See F
logs the dispense to the PC and returns the meter to 
its programmed entry screen.
Restricted Preset Dispense 
Mode
When meters are programmed in restricted preset 
mode, the specified dispense value cannot be 
increased, only decreased. The functionality of this fea-
ture is identical to Preset Dispense Mode (see Preset 
Dispense Mode
 beginning on page 14) except that the 
preset value can only decreased with the down keypad 
button.
Removing and Replacing the 
Battery
1.
Remove the battery by pressing in on both battery 
lock buttons (E) and pulling the battery (F) out and 
away from the meter. See F
IG
. 20.
2.
Place the battery in the battery charger. See 
Instruction Manual 309502 for details.
3.
Replace the battery by pressing in on both battery 
lock buttons (E) and pushing the battery (F) into the 
meter.
.
Quick-Lock
 Nozzle
1.
To close the nozzle to prevent dripping, rotate left 
(counter clockwise) until tight. See F
IG
. 21.
2.
To open the nozzle for dispensing, rotate right 
(clockwise) until fully open.
F
IG
. 18
F
IG
. 19
If END is not pressed, after 5 minutes the meter will 
time out and log the dispense to the PC.
If the meter displays a low battery warning, wait 30 
seconds before installing a new battery. See Bat-
tery Life Indicator page 10.
F
IG
. 20
The nozzle opens and closes with LESS THAN 
one turn.
F
IG
. 21
E
F
ti64318
Open 
Close
ti64319