GHP 10 Marine Autopilot System Installation Instructions
2.0 L or 1.2 L Pump Hydraulic Layout on SeaStar Power Assist-Enabled Boats
notes:
Power Assist module:
It may be necessary to remove the 
Power Assist module to gain access to 
the fittings, the hoses, and the bleed-
tee fitting.
Remove the bleed-tee fitting from the 
Power Assist module and relocate it to 
the return port on the pump.
2.0 L/1.2 L pump (and motor):
Install the pump to the steering lines 
between the cylinder and the Power 
Assist module.
Do not install the pump to the 
steering lines between the helm and 
the Power Assist module.
An unbalanced cylinder requires 
an unbalanced valve on the pump 
(See 
Mount the pump horizontally if 
possible. Do not mount the pump 
vertically with the pump end 
(hydraulic connections) down.
Shadow Drive:
Mount the Shadow Drive horizontally 
and as level as possible.
Install the Shadow Drive in either 
the port or the starboard hydraulic 
steering line.
Always install a length of hose 
between the helm and the Shadow 
Drive.
Do not install the Shadow Drive 
directly to the helm.
Install the Shadow Drive between the 
helm and the Power Assist module.
Do not install the Shadow Drive 
between the Power Assist module 
and the pump.
Do not install the Shadow Drive between the Power Assist module and the cylinder.
Notice
Do not turn the system on until you bleed all the air from the helm, the Shadow Drive, the pump, and all the hydraulic lines.  
See 
Balanced cylinder
Port fitting
Starboard fitting
.0 L/1. L pump 
(and motor)
Port line
Return line
Starboard line
Shadow Drive
Helm
S R P
Bleed-tee fitting 
(relocate to the pump)
Sea Star 
Power Assist 
module
H1
H
C
C1
Return line
Balanced cylinder
Port fitting
Starboard fitting
.0 L/1. L pump 
(and motor)
Port line
Return line
Starboard line
Shadow Drive
Helm
S R P
Bleed-tee fitting 
(relocate to the pump)
Sea Star 
Power Assist 
module
H1
H
C
C1
Return line