Graco SDM5 User Manual

Page of 44
Technical Data
312865R
43
Technical Data
*Tested in 10W motor oil. Flow rates vary with fluid pressure, temperature and viscosity.
**Battery required to meet life expectancy: Energizer
®
 Alkaline E91.
† At 2.5 gpm (9.5 lpm), at 70°F (21°C), with 10-weight oil and 1 gallon dispensed. May require calibration; out-of-box 
accuracy is +/- 1.25 percent.
Flow range*
0.26 to 14 gpm (1 to 53 lpm)
Maximum Working Pressure
1500 psi (10 MPa, 103.4 bar)
Maximum Working Pressure 
(50:50 antifreeze/water mix)
900 psi (6.2 MPa, 62 bar)
Units of Measure
pints, quarts, gallons, liters (factory set to quarts)
Weight
5 pounds (2.26 kg)
Dimensions (without extension)
Length
13 inches (33 cm)
Width
3.75 inches (9.5 cm)
Height
5.75 inches (14.6 cm)
Units of measure
factory set in quarts
maximum totalizer amount = 999,999 gallons or liters
maximum recorded dispensed volume = 999.99 units
maximum preset volume (Preset only) = 999.9 units
Inlet
1/2-14 npt or 3/4-14 npt,
or 1/2-14 BSPP or 3/4-14 BSPP,
or 1/2-14 BSPT or 3/4-14 BSPT
Outlet
3/4-16 straight thread o-ring boss
Operating temperature range
4 °F to 158°F (-16°C to 70°C)
Storage temperature range
-40°F to 158°F (-40°C to 70°C)
Battery**
4AA alkaline or lithium batteries
Expected battery life in typical shop 
environment
1 year
Wetted parts
aluminum, stainless steel, PBT/PC, zinc,
nitrile rubber, CS
Fluid compatibility
antifreeze, gear oil, crankcase oil, ATF
Meter pressure loss
80 psi @ 10 gpm
Accuracy†
+/- 0.5 percent