Graco g250 User Manual

Page of 18
Installation
308778L
5
Installation
Dust and Foreign Matter
Avoid having dust or foreign matter enter the flow meter 
by taking the following precautions: 
Thoroughly flush the fluid supply lines before install-
ing the flow meter. 
When installing fittings, make sure that no sealing 
tape overlaps into the inside of the pipe.
Install a 100 mesh fluid filter upstream of the flow 
meter.
Installing the Flow Meter
Flow volume can only be measured at the location 
where the flow meter is installed.
The Fluid Flow Meters are intrinsically safe for Class 
I; Division 1; Group D hazardous indoor (NEMA 1) 
locations when installed with an intrinsically safe 
power device and wiring.
Refer to ANSI standards ISA-RP12.6, NEC Article 
504 and the Canadian Electrical Code Appendix F.
Do not use more than 200 ft. (61 m) of cable.
Refer to F
. 1 to locate and install the flow meter, 
connectors, and fluid shutoff valves. Install a check 
valve to prevent backflow. The arrows on the flow 
meter and check valve show the direction of fluid 
flow.
The shutoff valves allow you to isolate the meter for 
service. 
Refer to the Technical Data and Dimensions 
Drawings for dimension, inlet/outlet size, tempera-
ture and other specifications.
All electrical equipment must only be installed by 
a qualified electrician.
Understand and follow your local code and safety 
regulations for hazardous location wiring of intrin-
sically safe circuits.
F
IG
. 1: Typical Installation
7379A
Cable
Electronic Sensor Device
Flow Meter
Fluid Line
Fluid Shutoff Valve
on outlet side
Ground Sheath
Check Valve
Fluid Shutoff Valve
on outlet side