Graco SDM15 User Manual

Page of 44
Installation 
10
312865R
3. Slowly open the main fluid valve.
a. Place the hose end (with no dispense valve 
connected) into a container for waste oil.
b. Secure the hose in the container so it will not 
come out during flushing. 
c. If you have multiple dispense positions, first 
flush the dispense position farthest from the 
pump and work your way toward the pump.
4. Slowly open the shut-off valve (B) at the dispense 
position. Flush out a sufficient amount of oil to 
ensure that the entire system is clean; then close 
the valve.
5. Repeat Step 4 at all other positions.
Installing Meter (F
)
1. Relieve pressure, page 9.
2. Slide the swivel boot (32) back, over the hose, small 
end first, to access the swivel fitting (a).
3. Apply thread sealant to the male threads of the hose 
fitting. Thread the hose fitting into the meter swivel 
(31). Use two wrenches to tighten securely (F
1.
a. Loosen nut (a) until it is completely off tube 
threads. 
b. Thread extension (20) into housing (b) until it 
bottoms out. 
c. Align extension (20) with meter housing and 
handle (c). 
d. Firmly tighten nut (a). 
F
IG
. 4
Make sure you let the sealant cure to the manufac-
turer’s recommendations before circulating fluid 
through the system.
31
ti10983a
32
a
F
IG
. 5
NOTICE
Do not use PTFE tape or thread sealant on threads of 
extension tube (20). This could cause the fitting to 
leak.
20
a
c
b
ti10615A