Graco G250HR User Manual

Page of 18
Technical Data 
16
308778L
Technical Data
*
For most commonly used coatings, the flow meter reading will be accurate to within +/- 0.5%. Accuracy will dimin-
ish at low viscosities and low flow rates.
Maximum Fluid Working Pressure
G3000 and G3000HR . . . . . . . . . . . . . . . . . . . . . . . 
G250 and G250HR . . . . . . . . . . . . . . . . . . . . . . . . . 
4000 psi (28 MPa, 276 bar)
250 psi (1.72 MPa, 17.2 bar)
Flow Range
G3000 and G250  . . . . . . . . . . . . . . . . . . . . . . . . . . 
G3000HR and G250HR . . . . . . . . . . . . . . . . . . . . . 
0.02-1.0 gal/min (75-3800 cc/min)
0.01-0.5 gal/min (38-1900 cc/min)
Fluid Temperature Range . . . . . . . . . . . . . . . . . . . . . . . 
40-180°F (4-80°C)
Maximum Ambient Temperature . . . . . . . . . . . . . . . . . . 
180°F (80°C)
Fluid Viscosity Range . . . . . . . . . . . . . . . . . . . . . . . . . . 
20-3000 cps (see Pressure Drop Curve on page 17)
Maximum Cable Length  . . . . . . . . . . . . . . . . . . . . . . . . 
200 ft (61 m)
Flow Meter Inlet/Outlet  . . . . . . . . . . . . . . . . . . . . . . . . . 
1/4 npt(f)
Resolution
G3000 and G250  . . . . . . . . . . . . . . . . . . . . . . . . . . 
G3000HR and G250HR . . . . . . . . . . . . . . . . . . . . . 
0.119 cc/pulse
0.061 cc/pulse
Accuracy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
+/- 0.5%*
Supply Voltage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
10-30 Vdc
Intrinsic Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Class I; Div. 1; Group D
V max = 30 V
I max = 15 mA
Ci = 0.2 microfarads
Li = 0 mH
Approvals  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
See front cover
Wetted Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
303 Stainless Steel, Tungsten Carbide, PTFE
Weight
G3000 and G3000HR . . . . . . . . . . . . . . . . . . . . . . . 
G250 and G250HR . . . . . . . . . . . . . . . . . . . . . . . . . 
6 lb (2.7 kg)
2.6 lb (1.8 kg)