Russound CAM6.6T-S1 User Manual

Page of 112
36
The RNET Link In and Link Out can be used to
connect two to six CAM6.6 or CAV6.6 con-
trollers. The connection is made using a CAT-5
patch cable from the Link Out of the master
CAM6.6 and into the Link In of the next con-
troller. Along with RNET data signals, the RNET
Link In and Link Out jack passes the six source
IR signals. These are only for source-specific IR
remote repeating, not codes initiated from the
controller’s internal IR library. The CAT-5 patch
cable should not exceed 18 inches in length to
avoid potential cross-talk between the source-
specific IR repeating signal lines. 
The RNET Link In and Link Out is also used to
connect the CAM6.6 to other Russound prod-
ucts with RNET.
Note: If two or more CAM6.6 or CAV6.6 con-
trollers will be connected using the RNET Link In
and Link Out ports, each controller must have a
unique Controller ID prior to being connected
through the RNET ports. The Controller ID
assignment must be performed during the
Controller Setup section of the Installation menu.
CAM6.6
CAV6.6 (Controller ID 2)
CAM6.6 (Controller ID 1)
CA
T-5 C
able (MAX LENGTH 18 INCHES)
INSTALLER
MAKING CONNECTIONS
RNET Link In and Link Out