Baja Marine 342 User Manual

Page of 85
342 Performance
®
1.2
S
ection
 1 • S
afety
2.  l
eGallY
 M
anDaTeD
 M
iniMuM
 
r
equireD
 e
quipMenT
The  following  equipment  is  the  minimum  required  by 
the U.s. Coast guard for a boat 26' to less than 40' [7.9 
meters to less than 12 meters] in length.
Personal Flotation Devices (PFDs):  One Coast guard 
approved Type I, II or III device is mandatory for each 
person aboard.  One throwable Type IV device is also 
required to be on board.  a Type V device is acceptable 
if worn for approved use.  see Page 1.4 for a description 
of these PFD classifications.  
Always wear a PFD when 
boating.  
Fire Extinguisher - Portable:  If no fixed fire extinguishing 
system is installed in the engine and generator spaces, 
the U.s. Coast guard requires 
two (2) Type B1 or one 
(1)  Type  B2  fire  extinguishers  be  on  board.    If  your 
boat is equipped with a fixed fire extinguishing system 
in  the  engine  and  generator  spaces,  the  U.s.  Coast 
guard requires 
one (1) Type B1 fire extinguisher be on 
board.  The american Boat and yacht Council (aByC) 
recommends that you have 
three (3) Type B1 ABC fire 
extinguishers on board located in the following areas:   
outside  the  engine  compartment,  at  the  helm  station, 
and in the galley.
Whistle, Horn:  you must have on board some means 
of making a loud sound signal, for example, whistle or 
horn.
Visual Distress Signals:  If you operate your boat in 
coastal waters or on the great lakes, you must have 
visual distress signals for day and night use on board.  at 
least three (3) U.s. Coast guard approved pyrotechnic 
devices, marked with date showing service life, must be 
carried, be readily accessible, in serviceable condition, 
and not expired.  store pyrotechnic signals in a well-
marked waterproof container in a dry location.
Other:  your Baja boat is equipped with the required 
navigation  lights,  engine  exhaust  and  ventilation 
systems.
3.  f
ire
 e
xTinGuishinG
 s
YsTeM
Your boat may be equipped with the optional automatic fire 
extinguisher system, located in the engine compartment.  
In the event of a fire, the heat sensitive automatic head in 
the engine compartment will release a fire-extinguishing 
vapor, totally flooding the area.
The  dashboard  contains  an  indicator  light  for  the 
automatic fire extinguishing system.  The light will be ON 
when the ignition is on and indicates that the system is 
ready.  If the light goes out while the ignition is on, the 
system has discharged.
When discharge occurs, immediately shut down all 
engines, powered ventilation, electrical systems, and 
extinguish all smoking materials.  Do not immediately 
open the engine compartment!  This feeds oxygen 
to the fire and the fire could restart.
Wait  at  least  fifteen  (15)  minutes  before  opening  the 
engine compartment.  This permits the fire-extinguishing 
vapor to "soak" the compartment long enough for hot 
metals and fuels to cool.  have portable extinguishers 
at hand and ready to use in case the fire re-ignites.  Do 
not breathe fumes or vapors caused by the fire.
4.  c
arbon
 M
onoxiDe
In  rainy  and/or  cold  weather,  fresh  air  must  circulate 
through boat to avoid carbon monoxide poisoning.
!
   
DANGER
!
   
DANGER
Sleeping on boat requires an operating Carbon Monoxide 
detection system in each sleeping location.
Fumes from engines, generators, and other equipment 
and  appliances  using  burning  fuel  contain  odorless, 
colorless carbon monoxide gas.
Carbon monoxide can cause brain damage or death.
Open all doors, curtains, windows, and hatches to let 
fresh air circulate, when running engine, generator or 
burning  any  fuel  when  boat  is  anchored,  moored  or 
docked.
DANGER
!
PFD REQUIREMENTS DIFFER
Depending on the state or country of operation 
the operator of a vessel may be fined for failure 
to comply with local or national rules regarding 
PFD usage.
NOTICE