DELL 7.4 User Manual

Page of 232
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap 
Numbers
753
Event ID — 2188
Description
The controller write policy has been changed to Write Through.
Severity
Warning
Cause and 
Action
Cause: The controller battery is unable to maintain cached data for the required 
period of time. For example, if the required period of time is 24 hours, the battery is 
unable to maintain cached data for 24 hours. It is normal to receive this alert during 
the battery Learn cycle as the Learn cycle discharges the battery before recharging 
it. When discharged, the battery cannot maintain cached data.
Action: Check the health of the battery. If the battery is weak, replace the battery 
pack.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
1153
Event ID — 2189
Description
The controller write policy has been changed to Write Back.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: This alert is for informational purposes.
Action: None
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
1151
Event ID — 2190
Description
The controller has detected a hot-add of an enclosure.
Severity
OK / Normal / Informational
104