Event ID — 2202
Description
A global hot spare has been removed.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: The controller is unable to communicate with a disk that is assigned as a 
global hot spare. The disk may have been removed. There may also be a bad or 
loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the 
cables. If necessary, replace the disk and reassign the hot spare.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
901
Event ID — 2203
Description
A dedicated hot spare failed.
Severity
Warning/ Non-critical
Cause and 
Action
Cause: The controller is unable to communicate with a disk that is assigned as a 
dedicated hot spare. The disk may have failed or been removed. There may also be 
a bad or loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the 
cables. If necessary, replace the disk and reassign the hot spare.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2048
Local Response Agent (LRA) Number: 2070
SNMP Trap 
Numbers
903
Event ID — 2204
Description
A dedicated hot spare has been removed.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: The controller is unable to communicate with a disk that is assigned as a 
dedicated hot spare. The disk may have been removed. There may also be a bad or 
loose cable.
Action: Check if the disk is healthy and that it has not been removed. Check the 
cables. If necessary, replace the disk and reassign the hot spare.