DELL 7.4 User Manual

Page of 232
Action: None
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2127
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
1201
Event ID — 2282
Description
Hot spare SMART polling failed.
Severity
Critical / Failure / Error
Cause and 
Action
Cause: The controller firmware attempted a SMART polling on the hot spare but 
was unable to complete it. The controller has lost communication with the hot 
spare.
Action: Check the health of the disk assigned as a hot spare. You may need to 
replace the disk and reassign the hot spare. Make sure the cables are attached 
securely. See the Server Administrator Storage Management User’s Guide, for more 
information on checking the cables.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2071
SNMP Trap 
Numbers
904
Event ID — 2283
Description
A redundant path is broken.
Severity
Warning / Non-critical
Cause and 
Action
Cause: The controller has two connectors that are connected to the same 
enclosure. The communication path on one connector has lost connection with 
the enclosure. The communication path on the other connector is reporting this 
loss.
Action: Make sure the cables are attached securely and both enclosure 
management modules (EMMs) are healthy. See the Cables Attached Correctly 
section for more information on checking the cables.
Related Alert 
Information
Clear Alert Number: 2284
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap 
Numbers
903
135