DELL 7.4 User Manual
Event ID — 2381
Description
Controller preserved cache is recovered.
Severity
OK / Normal / Informational
Cause and
Action
Action
Cause: This alert is provided for informational purposes.
Action: None.
Action: None.
Related Alert
Information
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
Numbers
751
Event ID — 2382
Description
An unsupported configuration was detected. The controller does not support
physical disks of type SSD: <Physical DiskID>, <controller- ID>, <connector- ID>
physical disks of type SSD: <Physical DiskID>, <controller- ID>, <connector- ID>
Severity
Warning / Non-critical
Cause and
Action
Action
Cause: A physical disk of media type SSD is attached to a controller that does not
support SSD disks.
Action: Replace the unsupported physical disk with a physical disk of media type
HDD.
support SSD disks.
Action: Replace the unsupported physical disk with a physical disk of media type
HDD.
Related Alert
Information
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap
Numbers
Numbers
903
Event ID — 2383
Description
The Information level set for the hot spare protection policy is violated for the
Virtual Disk.
Virtual Disk.
Severity
OK / Normal / Informational
Cause and
Action
Action
Cause: The number of physical disks you specified for the hot spare protection
policy is violated.
Action: Reassign the number of hot spares as specified in the protection policy for
that RAID level.
policy is violated.
Action: Reassign the number of hot spares as specified in the protection policy for
that RAID level.
Related Alert
Information
Information
Clear Alert Number: 2195
Related Alert Number: None
Local Response Agent (LRA) Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
169