DELL 7.4 User Manual

Page of 232
Previous state was: <State>
Processor sensor status: <status>
Severity
Warning
Cause
A processor sensor in the specified system is in a throttled state. The sensor 
location, chassis location, previous state and processor sensor status information is 
provided.
Event ID — 1604
Description
Processor sensor detected a failure value Sensor Location: 
<Location in chassis>
Chassis Location: <Name of chassis>
Previous state was: <State>
Processor sensor status: <status>
Severity
Error
Cause
A processor sensor in the specified system is disabled, has a configuration error, or 
experienced a thermal trip. The sensor location, chassis location, previous state and 
processor sensor status are provided.
Pluggable Device Messages
The pluggable device messages listed provides status and error information when some devices, such as 
memory cards, are added or removed.
Event ID — 1650
Description
Device plug event type unknown Device location: <Location in 
chassis, if available>
Chassis Location: <Name of chassis, if available>
Additional details: <Additional details for the events, if 
available>
Severity
Information
Cause
A pluggable device event message of unknown type was received. The device 
location, chassis location, and additional event details, if available, are provided.
Event ID — 1651
Description
Device added to system Device location: <Location in chassis>
Chassis Location: <Name of chassis>
Additional details: <Additional details for the events>
Severity
Information
48