DELL 7.4 User Manual

Page of 232
Event ID — 2056
Description
Virtual disk failed.
Severity
Critical / Failure / Error
Cause and 
Action
Cause: One or more physical disks included in the virtual disk have failed. If the 
virtual disk is non-redundant (does not use mirrored or parity data), then the failure 
of a single physical disk can cause the virtual disk to fail. If the virtual disk is 
redundant, then more physical disks have failed than can be rebuilt using mirrored 
or parity information.
Action: Create a new virtual disk and restore from a backup.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2048, 2049, 2050, 2076, 2079, 2081, 2129, 2346
Local Response Agent (LRA) Number: 2081
SNMP Trap 
Numbers
1204
Event ID — 2057
Description
Virtual disk degraded.
Severity
Warning / Non-critical
Cause and 
Action
Cause 1: This alert message occurs when a physical disk included in a redundant 
virtual disk fails. Because the virtual disk is redundant (uses mirrored or parity 
information) and only one physical disk has failed, the virtual disk can be rebuilt.
Action 1: Replace the failed drive. Rebuild of the virtual disk starts automatically.
NOTE: If you put the drive in a different slot, you need to assign it as a hot 
spare for the rebuild to start automatically.
If you put the drive in a different slot, you need to assign it as a hot spare for the 
rebuild to start automatically.
Cause 2: A physical disk in the disk group has been removed.
Action 2: If a physical disk was removed from the disk group, either replace the disk 
or restore the original disk. You can identify which disk has been removed by 
locating the disk that has a red “X” for its status. Perform a rescan after replacing 
the disk.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: 2048, 2049, 2050, 2076, 2079, 2081, 2123, 2129, 2346
Local Response Agent (LRA) Number: 2080
SNMP Trap 
Numbers
1203
61