DELL 7.4 User Manual

Page of 232
Cause and 
Action
Cause: The physical disk enclosure is either hotter or cooler than the maximum or 
minimum allowable temperature range.
Action: Check for factors that may cause overheating or excessive cooling. For 
example, verify that the enclosure fan is working. You should also check the 
thermostat settings and examine whether the enclosure is located near a heat 
source. Make sure the enclosure has enough ventilation and that the room 
temperature is not too hot or too cold. See the enclosure documentation for more 
diagnostic information.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2091
SNMP Trap 
Numbers
854
Event ID — 2114
Description
A consistency check on a virtual disk has been paused (suspended).
Severity
OK / Normal / Informational
Cause and 
Action
Cause: The check consistency operation on a virtual disk was paused by a user.
Action: To resume the check consistency operation, right-click the virtual disk in 
the tree view and select Resume Check Consistency.
Related Alert 
Information
Clear Alert Number: 2115
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
1201
Event ID — 2115
Description
A consistency check on a virtual disk has been resumed.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: The check consistency operation on a virtual disk has resumed processing 
after being paused by a user. This alert is for informational purposes.
Action: None
Related Alert 
Information
Clear Alert Number: Alert 2115 is a clear alert for alert 2114.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
1201
78