DELL 7.4 User Manual

Page of 232
SNMP Trap 
Numbers
1053
Event ID — 2124
Description
Redundancy normal.
Severity
OK / Normal / Informational
Cause and 
Action
Cause: Data redundancy has been restored to a virtual disk or an enclosure that 
previously suffered a loss of redundancy. This alert is for informational purposes.
Action: None
Related Alert 
Information
Clear Alert Number: Alert 2124 is a clear alert for alerts 2122 and 2123.
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
1304
Event ID — 2125
Description
Controller cache preserved for missing or offline virtual disk.
Severity
Warning / Non-critical
Cause and 
Action
Cause: Virtual disk controller was disconnected, during I/O operation.
Action: Import foreign disks, if any. Check if the enclosure containing the virtual 
disk is disconnected from the controller.
Related Alert 
Information
Clear Alert Number: 2186, 2240
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
1203
Event ID — 2126
Description
SCSI sense sector reassign.
Severity
Warning / Non-critical
Cause and 
Action
Cause: A sector of the physical disk is corrupted and data cannot be maintained on 
this portion of the disk. This alert is for informational purposes.
CAUTION: Any data residing on the corrupt portion of the disk may be lost 
and you may need to restore your data from backup.
Action: If the physical disk is part of a non-redundant virtual disk, then back up the 
data and replace the physical disk.
82