Delay Units and Ranges
Delay values are correlated, allowing automatic conversion from one measurement unit to
another when changing the unit measure. Delay units and value ranges are as follows:
Table 3.1. Delay Unit Ranges
Range
Unit
0.00−2000.00 ms
Milliseconds (ms)
0.00−686.4 m
Meters (m)
0.00−2 251.97 ft
Feet (ft)
0.00−02:00.00
Frames (24 fps)
0.00−02:00.00
Frames (25 fps)
0.00−02:00.00
Frames (30 fps)
0.00−192 000
Samples (96 kHz)
Setting Input Channel Delay
1.
Select the [Galileo Unit] > Input Processing > Channel Settings page.
2.
Select the desired units measure (milliseconds, feet, meters, frames, or samples).
3.
Set the Delay value.
Setting Output Channel Delay
1.
Select the [Galileo Unit] > Output Processing > Channel Settings page.
2.
Select the desired units measure (milliseconds, feet, meters, frames, or samples).
3.
Set the Delay value.
Copy, Paste, Load, Save, and Reset Control Values
Many controls in Compass support the use of right-click to copy, paste, save, load, and reset
control values or the values of a set of controls.
The Paste, Copy, Save, Load, and Reset actions are described as “Copy/Reset” in the following
task descriptions (pasting and loading implies the value was copied in the first place.)