Garmin GTX 23 User Manual
190-00906-01
GTX 23 Installation Manual
Rev. C
Page B-10
B.6 Daisy Chain between Methods A and B
In rare situations where more braids need to be terminated for a connector than three per ring terminal and
a mixture of Methods A and B have been used, it is allowable to daisy chain a maximum of two shields
together from a Method A termination to a Method B (Figure B-7). All other restrictions and instructions
for the shield termination technique set forth for Method A and B are still applicable.
a mixture of Methods A and B have been used, it is allowable to daisy chain a maximum of two shields
together from a Method A termination to a Method B (Figure B-7). All other restrictions and instructions
for the shield termination technique set forth for Method A and B are still applicable.
NOTE
The maximum length of the combined braids should be approximately 4 inches.
Figure B-7 Daisy Chain between Methods A and B
B.7 Splicing Signal Wires
NOTE
Figure B-8 illustrates that a splice must be made within a 3 inch window from outside the
edge of clamp to the end of the 3 inch max mark.
edge of clamp to the end of the 3 inch max mark.
WARNING
Keep the splice out of the backshell for pin extraction, and outside of the strain relief to
avoid preloading.
avoid preloading.
Figure B-8 shows a two wire splice, but a maximum of three wires can be spliced. If a third wire is spliced,
it is located out front of splice along with signal wire going to pin.
it is located out front of splice along with signal wire going to pin.
Splice part numbers:
• Raychem D-436-36/37/38
• MIL Spec MIL-S-81824/1
• MIL Spec MIL-S-81824/1
This technique may be used with shield termination methods: A.1, A.2, B.1, and B.2.