4. Tighten the locking screw against the bottom collar of the 
20 lb LP gas fuel tank to secure.
5. Slide tank tray back into the cabinet.
6. Close cabinet doors.
Local LP Gas Supply Conversion
Conversion must be made by a qualified gas technician. The 
qualified gas technician shall provide the gas supply to the 
selected grill location in accordance with the National Fuel Gas 
Code ANSI Z223.1/NFPA 54 - latest edition, and local codes. For 
conversion to local LP, the convertible regulator in the conversion 
kit supplied with the grill must be used.
IMPORTANT: The gas installation must conform with local 
codes, or in the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The qualified 
LP gas technician shall provide the LP gas supply to the selected 
grill location in accordance with the National Fuel Gas Code, 
ANSI Z223.1/NFPA 54 and local codes.
Follow instructions for converting to local LP gas in the “Gas 
Conversions” section.
The gas supply line shall be equipped with an approved shutoff 
valve. This valve should be located in the same area as the grill 
and should be in a location that allows ease of opening and 
closing. Do not block access to the shutoff valve. The valve is for 
turning on or shutting off gas to the grill.
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The 
qualified Natural gas technician shall provide the Natural gas 
supply to the selected grill location in accordance with the 
National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, 
and local codes. For conversion to Natural gas, the Natural gas 
conversion kit supplied with the grill must be used.
IMPORTANT: The gas installation must conform with local 
codes, or in the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit 
supplied with the grill must be used. Follow instructions for 
converting to Natural gas in the “Gas Conversions” section.
The gas supply line shall be equipped with an approved shutoff 
valve. This valve should be located in the same area as the grill 
and should be in a location that allows ease of opening and 
closing. Do not block access to the shutoff valve. The valve is for 
turning on or shutting off gas to the grill.
A. Locking screw
B. Mounting hole
C. Bottom collar
A. New CSA International approved 
“outdoor” flexible gas supply line 
B. Rear of grill
C. To local LP gas supply
A
B
C
B
C
A
A. Gas supply line
B. Shutoff valve “open” position
C. To grill
A. New CSA International approved 
“outdoor” flexible gas supply line 
B. Rear of grill
C. To Natural gas supply
A. Gas supply line
B. Shutoff valve “open” position
C. To grill
A
B
C
B
C
A
A
B
C