The 20 lb LP gas fuel tank must be mounted and secured.
Door Style Tank Tray
1. Open cabinet doors.
2. Pull out the tank tray.
3. Place the 20 lb LP gas fuel tank bottom collar into the 
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of the 
20 lb LP gas fuel tank to secure.
5. Slide tank tray back into the cabinet.
6. Close cabinet doors.
Local LP Gas Supply Conversion
Conversion must be made by a qualified gas technician. The 
qualified gas technician shall provide the gas supply to the 
selected side burner location in accordance with the National 
Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local 
codes. For conversion to local LP, the convertible regulator in the 
conversion kit supplied with the side burner must be used.
IMPORTANT: The gas installation must conform with local 
codes, or in the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The qualified 
LP gas technician shall provide the LP gas supply to the selected 
side burner location in accordance with the National Fuel Gas 
Code, ANSI Z223.1/NFPA 54 and local codes.
Follow instructions for converting to local LP gas in the “Gas 
Conversions” section.
The gas supply line shall be equipped with an approved shutoff 
valve. This valve should be located in the same area as the side 
burner and should be in a location that allows ease of opening 
and closing. Do not block access to the shutoff valve. The valve 
is for turning on or shutting off gas to the side burner.
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The 
qualified Natural gas technician shall provide the Natural gas 
supply to the selected side burner location in accordance with 
the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest 
edition, and local codes. For conversion to Natural gas, the 
Natural gas conversion kit supplied with the side burner must be 
used.
IMPORTANT: The gas installation must conform with local 
codes, or in the absence of local codes, with the National Fuel 
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit 
supplied with the side burner must be used. Follow instructions 
for converting to Natural gas in the “Gas Conversions” section.
The gas supply line shall be equipped with an approved shutoff 
valve. This valve should be located in the same area as the side 
burner and should be in a location that allows ease of opening 
and closing. Do not block access to the shutoff valve. The valve 
is for turning on or shutting off gas to the side burner.
Tank tray
A. Locking screw
B. Mounting hole
C. Bottom collar
A. New CSA International approved 
“outdoor” flexible gas supply line 
B. Rear of side burner
C. To local LP gas supply
A
B
C
B
C
A
A. Gas supply line
B. Shutoff valve “open” position
C. To side burner
A. New CSA International approved 
“outdoor” flexible gas supply line 
B. Rear of side burner
C. To Natural gas supply
A. Gas supply line
B. Shutoff valve “open” position
C. To side burner
A
B
C
B
C
A
A
B
C