Desa VC42P SERIES User Manual

Page of 40
www.desatech.com
116236-01A
24
O
F
  PILOT   
LO 
IH 
O
N
     
    
    
   
Figure 45 - Control Valve
Piezo 
Ignitor
Gas Control 
Knob
Variable Control Knob
OPERATING FIREPLACE
Lighting Instructions (Cont.)
To Turn Off Gas To Appliance
Manual Lighting Procedure
Optional Hand-Held Remote Operation
OF
F   
PIL
O
T
   
LO
 
IH
 
ON
OFF
REMOTE
ON
OFF
O
N  
          
    
Blower Control Knob
(Optional Accessory)
Variable 
Control Knob
Selector Switch 
in Remote 
Position
Gas Control Knob 
in ON Position 
Figure 46 - Setting the Selector Switch, Gas Control Knob and 
Variable Control Knob for Remote Operation
OPERATING FIREPLACE
Continued
7.  Turn gas control knob counterclockwise 
 to “PILOT” 
(see Figure 45).
8.  Push in gas control knob all the way and hold. Immediately 
light the pilot by repeatedly depressing the piezo spark 
ignitor until a flame appears. Continue to hold for about 
one (1) minute after the pilot is lit. Release gas control knob 
and it will pop back. Pilot should remain lit. If it goes out, 
repeat steps 5 through 8.
•  If gas control knob does not pop up when released, stop and 
immediately call your service technician or gas supplier.
•  If the pilot will not stay lit after several tries, turn the gas 
control knob to “OFF” and call your service technician 
or gas supplier.
9.  Turn on all electric power to the fireplace.
10.  Turn gas control knob counterclockwise 
 to “ON”.
11.  This valve is equipped with a HI/LO feature. Set fireplace 
input as desired.
12.  Close lower louver panel.
TO TURN OFF GAS
TO APPLIANCE
1.  Open lower louver panel.
2.  Set selector switch in the OFF position to prevent draining 
battery.
3.  Turn off all electrical power to the appliance if service is to 
be performed.
4.  Push in gas control knob slightly and turn clockwise 
 
to “OFF”.
5.  Close lower louver panel.
Shutting Off Burners Only (pilot stays lit)
You may shut off the burners and keep the pilot lit by doing 
one of the following:
1.  Turn gas control knob clockwise 
 to the PILOT position.
2.  Set selector switch in the OFF position.
MANUAL LIGHTING
PROCEDURE
1.  Remove glass door (see Removing/Replacing Glass Door, 
page 21).
2.  Follow steps 1 through 8 under Lighting Instructions, page 23.
3.  Depress gas control knob and light pilot with match.
4.  Keep gas control knob pressed in for 30 seconds after light-
ing pilot. After 30 seconds, release gas control knob. Follow 
steps 10 through 12 under Lighting Instructions,.
5.  Replace glass door (see Removing/Replacing Glass Door, 
page 21).
OPTIONAL HAND-HELD 
REMOTE OPERATION
Note:
 All remote control accessories must be purchased sepa-
rately (see Accessories, page 36). Follow instructions included 
with the remote control. 
NOTICE:  You  must  light  the  pilot  before  using  the 
hand-held  remote  control  unit.  See 
Lighting  Instruc-
tions, page 23.
After lighting, let pilot flame burn for about one minute. Turn 
control knob to ON position. Adjust flame adjustment knob 
anywhere between HI and LO. Slide the selector switch to the 
REMOTE position (see Figure 46). Note: The burner may light 
if hand-held remote was on when selector switch was last turned 
off. You can now turn the burner on and off with the hand-held 
remote control unit. 
IMPORTANT:
 
Do not leave the selector switch in the REMOTE 
or ON position when the pilot is not lit. This will drain the 
battery.