Desa VSGF36PRA User Manual

Page of 40
www.desatech.com
116746-01A
4
1.  This appliance is only for use with the type of 
gas indicated on the rating plate. This appliance 
is not convertible for use with other gases.
2.  Do not place propane/LP supply tank(s) in-
side any structure. Locate propane/LP supply 
tank(s) outdoors (propane/LP units only).
3.  If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not use 
any phone in your building
• immediately call your gas supplier from a 
neighborʼs phone. Follow the gas supplierʼs 
instructions
• if you cannot reach your gas supplier, call 
the fire department
4.  This fireplace shall not be installed in a bed-
room or bathroom.
5.  Do not use this fireplace as a wood-burning 
fireplace. Use only the logs provided with the 
fireplace. 
6.  Do not add extra logs or ornaments such as 
pine cones, vermiculite or rock wool. Using 
these added items can cause sooting. Do not 
add lava rock around base. Rock and debris 
could fall into the control area of fireplace.
7.  To prevent the creation of soot, follow the 
instructions in  Cleaning and maintenance
page 25.
8.  Before  using  furniture  polish,  wax,  carpet 
cleaner or similar products, turn heater off. If 
heated, the vapors from these products may 
create a white powder residue within burner 
box or on adjacent walls or furniture.
9.  This fireplace needs fresh air ventilation to run 
properly. This fireplace has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The 
ODS shuts down the fireplace if enough fresh 
air is not available. See Air for Combustion 
and  Ventilation,  page  7.  If  fireplace  keeps 
shutting off, see Troubleshooting, page 27.
10.  Do not run fireplace
• where flammable liquids or vapors are used 
or stored
• under dusty conditions
11.  Do not use this fireplace to cook food or burn 
paper or other objects.
SAFETY INFORMATION
Continued
12.  Do  not  use  fireplace  if  any  part  has  been 
exposed to or under water. Immediately call 
a qualified service technician to inspect the 
fireplace and to replace any part of the control 
system and any gas control which has been 
under water. 
13.  Do not operate fireplace if any log is broken. 
Do not operate fireplace if a log is chipped 
(dime-sized or larger). 
14.  Turn fireplace off and let cool before servicing. 
Only a qualified service person should service 
and repair fireplace.
15.  Operating fireplace above elevations of 4,500 
feet could cause pilot outage. 
16.  To prevent performance problems in propane/LP 
units, do not use propane/LP fuel tanks of less 
than 100 lbs. capacity (propane/LP units only).
17.  Provide  adequate  clearances  around  air 
openings.
LOCAL CODES
Install and use fireplace with care. Follow all local 
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code ANSI 
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY  10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA  02269
Note:
 Where listed vented decorative logs are 
required, thermostat operation is not permitted.
State  of  Massachusetts:  The  installa-
tion must be made by a licensed plumber 
or  gas  fitter  in  the  Commonwealth  of 
Massachusetts.
Sellers  of  unvented  propane  or  natural 
gas-fired supplemental room heaters shall 
provide to each purchaser a copy of 527 
CMR 30 upon sale of the unit.
Vent-free  gas  products  are  prohibited  for 
bedroom  and  bathroom  installation  in  the 
Commonwealth of Massachusetts.