Recommended Ground Method
The outdoor side burner, when installed, must be electrically 
grounded in accordance with local codes or, in the absence of 
local codes, with the National Electrical Code ANSI/NFPA 70, or 
Canadian Electrical Code, CSA C22.1.
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio 44131-5575
National Fire Protection Association
One Batterymarch Park
Quincy, Massachusetts 02269
Gas Supply Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149.1 - latest 
edition.
IMPORTANT: The side burner must be connected to a regulated 
gas supply.
Refer to the model/serial rating plate for information on the type 
of gas that can be used. If this information does not agree with 
the type of gas available, check with your local gas supplier.
Gas Conversion:
No attempt shall be made to convert the side burner from the gas 
specified on the model/serial rating plate for use with a different 
gas type without consulting the serving gas supplier. The 
conversion kits supplied with the side burner must be used. See 
“Gas Conversions” section for instructions.
Gas Pressure Regulator
The gas pressure regulator supplied with this side burner must be 
used. The inlet (supply) pressure to the regulator should be as 
follows for proper operation:
LP Gas:
Set pressure: 11" (27.9 cm) WCP
Inlet (supply) pressure: 11" to 14" (27.9 cm to 35.5 cm) WCP
Natural Gas:
Set pressure: 4" (10.2 cm) WCP
Inlet (supply) pressure: 7" to 14" (17.8 cm to 35.5 cm) 
WCP maximum.
Contact local gas supplier if you are not sure about the inlet 
(supply) pressure.
Burner Requirements for High Altitude
Input ratings shown on the model/serial rating plate are for 
elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced at a 
rate of 4% for each 1,000 ft (304.8 m) above sea level. Orifice 
conversion is required. See “Assistance or Service” section to 
order.
Gas Supply Line Pressure Testing
Testing above ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge):
The side burner and its individual shutoff valve must be 
disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures greater than 
½ psi (3.5 kPa).
Testing below ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge) or 
lower:
The side burner must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve during any 
pressure testing of the gas supply piping system at test 
pressures equal to or less than ½ psi (3.5 kPa).
Gas Connection Requirements
For Models Equipped for LP Gas
20 lb LP Gas Fuel Tank
This side burner is equipped for use with a 20 lb LP gas fuel tank 
(fuel tank not supplied). A gas pressure regulator/hose assembly 
is supplied.
It is also design-certified by CSA International for local LP gas 
supply or for Natural gas with appropriate conversion.
A. 3 prong ground plug
B. 3-prong polarized type outdoor GFI outlet
C. Ground prong
A
B
C
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor” 
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 11” (28 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A. Gas pressure regulator/hose assembly
A