INSERT INSTALLATIONS 
 
Insert installations must be vented with 3” or 4” pipe. Pipe may 
be single wall stainless steel flexible pipe. Vent may terminate 
within chimney beyond a blanking plate or extend to the chimney 
top. See “COMBUSTION AIR SUPPLY” for outside air access 
information. 
 
The fireplace and chimney should be cleaned thoroughly before 
starting the installation. We suggest painting the interior of 
particularly old and dirty fireplaces to seal any odors. In zero-
clearance fireplace installations, when the fireplace opening is 
above the floor or raised hearth, the adjustable “Breckwell P23 Z-
C Legs” (part # A-S-ZCLEGS) can be used to bridge the gap 
between the hearth and stove bottom. (Refer to figure 14) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
A. 
ASSEMBLING THE FLASHING SET 
 
Follow the instructions packaged with the P23 Flashing set part 
C-P23-MEDFL-C or C-P23-LGFL-C. 
(Refer to Figure 15) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
FIGURE 14 
FIGURE 15 
INSTALLATION 
11