FMI MF42ONE User Manual

Page of 28
www.fmiproducts.com
125636-01A
19
POSSIBLE CAUSE
1. Manifold pressure is too low
2. Burner orifice clogged
1. Burner orifice is clogged or dam-
aged
2. Damaged burner
1. Residues  from  manufacturing 
processes and logs curing
1. Air in gas line
2. Air  passageways  on  appliance 
blocked
3. Dirty  or  partially  clogged  burner 
orifice.
1. When heated, vapors from furni-
ture polish, wax, carpet cleaners, 
etc. may turn into white powder 
residue
1. Battery  is  not  installed.  Battery 
power is low
1. Metal expanding while heating or 
contracting while cooling
2. Ignitor Assembly  is  out  of  posi-
tion
3. Wind  is  disturbing  the  burner 
flame and the ignitor assembly is 
relighting the burner
4.  Wire  connection  loose  or  wire 
broken
REMEDY 
1. Contact local natural or propane/
LP gas company
2. Clean burner (see Cleaning and 
Maintenance, page 16) or replace 
burner orifice(s)
1. Clean burner (see Cleaning and 
Maintenance, page 16) or replace 
burner orifice
2. Replace damaged burner
1. Problem will stop after a few hours 
of operation
1. Operate  burners  until  air  is  re-
moved  from  line.  Have  gas  line 
checked by local natural or pro-
pane/LP gas company
2. Observe  minimum  installation 
clearances (see pages 9 through 
11)
3. Clean burner (see Cleaning and 
Maintenance, page 16) or replace 
burner orifice(s)
1. Turn appliance off when using fur-
niture polish, wax, carpet cleaners 
or similar products
1. Replace batteries in battey pack  
and in hand-held remote
1. This is normal with most applianc-
es.  If  noise  is  excessive,  contact 
qualified service person
2. Check ignitor position and adjust 
if  needed.  See  Figure  29  page 
15.
3. Should  wind  disturb  the  burner 
flame,  the  ignitor  will  automati-
cally spark to relight the burner. 
This is normal when the appliance 
is installed outdoors in windy con-
ditions.
4.  Check  wiring  connections  (see 
wiring  diagram,  page  17).  Re-
place wire harness if necessary.
OBSERVED PROBLEM
Delayed ignition of burner
Burner  backfiring  during  combus-
tion
Slight smoke or odor during initial 
operation
Appliance  produces  a  whistling 
noise when burners are lit
White powder residue forming within 
burner box or on adjacent walls or 
furniture
Remote does not function 
Appliance produces a clicking/tick-
ing  noise  just  after  burners  are  lit 
or shut off
TROUBLESHOOTING
Continued